Generac Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator

 


 

 

 

Diesel Generator Soundproof Quiet Generators Home Standby Emergency Backup Power Generators  Backup Generators by Generac Guardian       Commercial Generators    Home Standby Generators by Briggs & StrattonTrailerized Generators
 

Generac 5870 8,000 Watt Air-Cooled Propane/Natural Gas Powered Home Automatic Standby Generator With Transfer Switch (CARB Compliant) Generac 5870 8,000 Watt Air-Cooled Propane/Natural Gas Powered Home Automatic Standby Generator With Transfer Switch (CARB Compliant)
Buy new: $2,159.00
Usually ships in 24 hours
Guardian QuietSource Liquid-Cooled Light Commercial 18,000 Watt Stand By Generator With Gray Aluminum Enclosure 5399 Guardian QuietSource Liquid-Cooled Light Commercial 18,000 Watt Stand By Generator With Gray Aluminum Enclosure 5399
Buy new: $6,971.35
Usually ships in 24 hours
Generac QT04842ANAX 48,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator Generac QT04842ANAX 48,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator
Buy new: $13,871.00
Usually ships in 1 to 2 days
Generac Commercial Series Liquid-Cooled Standby Generator 60 kW, 277/480 Volts, LP, Model# QT06030KVSN Generac Commercial Series Liquid-Cooled Standby Generator 60 kW, 277/480 Volts, LP, Model# QT06030KVSN
Buy new: $14,799.99
Usually ships in 3-5 weeks
Generac Guardian Series QT03016 30,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant) Generac Guardian Series QT03016 30,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant)
Buy new: $8,927.00
Usually ships in 24 hours
Generac QT04524Y 45,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant) Generac QT04524Y 45,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant)
Buy new: $12,681.23
Usually ships in 24 hours
Generac 4582-2 Ultra Source 15,000 Watt Portable Generator (CARB Compliant) Generac 4582-2 Ultra Source 15,000 Watt Portable Generator (CARB Compliant)
Buy used from: $4,500.00
Generac QT03016ANSX 30,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant) Generac QT03016ANSX 30,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant)
Buy new: $8,927.00
Usually ships in 1 to 2 days
Generac QuietSource Series QT02516 25,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant) Generac QuietSource Series QT02516 25,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant)
Buy new: $7,919.00
Usually ships in 1 to 2 days
Generac QT02516ANSX 25,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant) Generac QT02516ANSX 25,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant)
Buy new: $7,919.00
Usually ships in 1 to 2 days
1   2   Next > >
 

Portable Generators | Standby Generators |  Air Compressors | UPS Uninterruptible Power Sources  |  Automotive Parts

Home Standby Power Rating 70 kW 60 Hz Call NOW!

Guardian  |  Guardian  Elite  |  QuietSource  |  Commercial  |  Specs  |  Transfer Switches

Liquid Cooled Gas Engine Generator Sets

Generators

Home  |  email  |  Buy Commercial Generators Online

30kW - 3.0L Liquid Cooled 40kW - 3.9L Liquid Cooled 50kW - 3.0L Liquid Cooled 55kW - 5.4L Liquid Cooled 70kW - 3.9L Liquid Cooled 70kW - 6.8L Liquid Cooled 80kW - 5.4L Liquid Cooled 100kW - 5.4L Liquid Cooled 100kW - 6.8L Liquid Cooled 130kW - 6.8L Liquid Cooled 150kW - 6.8L Liquid Cooled 11 kW 15, 20 & 25 kW 30 kW & 40 kWTransfer Switches  |  Generator Control Panel

 

UL 2200 Listed - 60 dB(A) at 23 feet

Quiet-Test Mode  For Low Noise Exercise -60 dB(A) at 23 feet

Generac 6.8L Engine Naturally Aspirated Gaseous Fueled

STANDARD EQUIPMENT

  • All input connections in one single area
  • High coolant temperature shutdown
  • Low oil pressure shutdown
  • Low coolant level automatic shutdown
  • Overspeed automatic shutdown
  • Adjustable cranking timer
  • Adjustable exercise timer
  • Oil drain extension
  • Cool flow radiator
  • Closed coolant recovery system
  • UV/Ozone resistant hoses

FEATURES

  • Watertight state of the art electrical connectors
  • Mainline circuit breaker
  • Oil drain extension to frame rail
  • Radiator drain extension
  • Battery charge alternator
  • 2 Amp static battery charger
  • Battery and battery cables
  • Battery rack
  • Fan and belt guards
  • Isochronous governor
Innovative design and fully prototype tested Built-in kW, kVAR and power factor meters
UL2200 Listed Watertight electrical connectors
Solid state frequency compensated digital Rodent proof construction
voltage regulator High efficiency, low distortion Generac designed alternator
Dynamic and static battery charger Vibration isolated from mounting base
Sound attenuated acoustically designed enclosure Matching Generac transfer switches engineered and
Quiet test for low noise level exercise tested to work as a system
Acoustically designed engine cooling system All components easily accessible for maintenance
High flow low noise factory engineered exhaust system Electrostatically applied powder paint
State of the art digital control system H-100 microprocessor control panel
 

APPLICATION & ENGINEERING DATA 70 kW

GENERATOR SPECIFICATIONS

TYPE ..........................................................................................................Synchronous

ROTOR INSULATION ..........................................................................................Class H

STATOR INSULATION ........................................................................................Class H

TOTAL HARMONIC DISTORTION ........................................................................<3.5%

TELEPHONE INTERFERENCE FACTOR (TIF) ........................................................<50

ALTERNATOR OUTPUT LEADS 3 PHASE............................................................4 wire

BEARINGS ....................................................................................................Sealed Ball

COUPLING ..................................................................................................Flexible Disc

LOAD CAPACITY (STANDBY RATING) ................................................................70 kW

EXCITATION SYSTEM............................................................................................Direct

NOTE: Emergency loading in compliance with NFPA 99, NFPA 110,

paragraph 5-13.2.6. Generator rating and performance in accordance

with ISO8528-5, BS5514, SAE J1349, ISO3046, and DIN6271 standards.

GENERATOR FEATURES

Revolving field heavy duty generator

Directly connected to the engine

Operating temperature rise 120 �C above a 40 �C ambient

Insulation is Class H rated at 150 �C rise

All prototype models have passed three phase short circuit testing

VOLTAGE REGULATOR

TYPE ..............................................................................................................Full Digital

SENSING ............................................................................................................3 Phase

REGULATION ......................................................................................................� 1/4%

FEATURES ......................................................................Built into H-100 Control Panel

V/F Adjustable

Adjustable Voltage and Gain

CONTROL PANEL FEATURES

TWO FOUR LINE LCD DISPLAYS READ:

Voltage (all phases) Current (all phases)

Power factor kW

kVAR Transfer switch status

Engine speed Low fuel pressure

Run hours Service reminders

Fault history Oil pressure

Coolant temperature Time and date

Low oil pressure shutdown High coolant temperature shutdown

Overvoltage Overspeed

Low coolant level Low coolant level

Not in auto position (flashing light)

INTERNAL FUNCTIONS:

I2T function for alternator protection from line to neutral and line to line short circuits

Emergency stop

Programmable auto crank function

2 wire start for any transfer switch

Communicates with the Generac HTS transfer switch

Built-in 7 day exerciser

Adjustable engine speed at exerciser

RS232 port for GenLink� control

RS485 port remote communication

Canbus addressable

Governor controller and voltage regulator are built into the master control board

Temperature range -40 �C to 70 �C

ENGINE SPECIFICATIONS

MAKE ................................................................................................................ Generac

MODEL..................................................................................................................V Type

CYLINDERS ................................................................................................................10

DISPLACEMENT ................................................................................................6.8 Liter

BORE ........................................................................................................................3.55

STROKE....................................................................................................................4.17

COMPRESSION RATIO ..............................................................................................9:1

INTAKE AIR SYSTEM........................................................................Naturally Aspirated

VALVE SEATS ..................................................................................................Hardened

LIFTER TYPE ....................................................................................................Hydraulic

GOVERNOR SPECIFICATIONS

TYPE ................................................................................................................Electronic

FREQUENCY REGULATION ..................................................................................� 1%

STEADY STATE REGULATION ............................................................................� 1/2%

ADJUSTMENTS

Speed......................................................................................................Yes

Droop ......................................................................................................Yes

ENGINE LUBRICATION SYSTEM

OIL PUMP ................................................................................................................Gear

OIL FILTER ..........................................................................................Full flow cartridge

CRANKCASE CAPACITY ..................................................................................5 Quarts

ENGINE COOLING SYSTEM

TYPE ....................................................................................................................Closed

WATER PUMP ................................................................................................Belt driven

FAN SPEED..............................................................................................................2200

FAN DIAMETER................................................................................................22 inches

FAN MODE............................................................................................................Pusher

FUEL SYSTEM

FUEL TYPE....................................................................................................Natural gas

CARBURETOR ..............................................................................................Down Draft

SECONDARY FUEL REGULATOR ..................................................................Standard

FUEL SHUT OFF SOLENOID ..........................................................................Standard

OPERATING FUEL PRESSURE..................................................................5� - 14� H2O

ELECTRICAL SYSTEM

BATTERY CHARGE ALTERNATOR ............................................................12V 30 Amp

STATIC BATTERY CHARGER........................................................................12V 2 Amp

RECOMMENDED BATTERY ......................................................................24F 625CCA

SYSTEM VOLTAGE ............................................................................................12 Volts

 

APPLICATION & ENGINEERING DATA GENERATOR SPECIFICATIONS

KW RATING

70

ENGINE SIZE

6.8 Liter V-10

GENERATOR OUTPUT VOLTAGE/KW - 60Hz

KW

AMP

CB Size

120/240V, 1-phase, 1.0 pf

70

292

300

120/208V, 3-phase, 3.0 pf

70

243

250

277/480V, 3-phase, 3.0 pf

70

105

125

GENERATOR LOCKED ROTOR KVA

AVAILABLE @ VOLTAGE DIP OF 35%

Single phase or 208 3-phase

145

480V 3-phase

160

ENGINE FUEL CONSUMPTION (Natural Gas)

Exercise cycle

ft3/hr.

240

25% of rated load

ft3/hr.

260

50% of rated load

ft3/hr.

500

75% of rated load

ft3/hr.

696

100% of rated load

ft3/hr.

1020

ENGINE COOLING

Air flow (inlet air including alternator and combustion air)

ft3/min.

5200

Coolant capacity

US gal.

4.5

Heat rejection to coolant

BTU/hr.

281,500

Max. operating air temp. on radiator

�C (�F)

60 (150)

Max. ambient temperature

�C (�F)

50 (140)

COMBUSTION AIR REQUIREMENTS

Flow at rated power 60 Hz

cfm

205

SOUND EMISSIONS IN DBA

Exercising at 7 meters

60

Full load at 7 meters

73

EXHAUST

Exhaust flow at rated output 60 Hz

cfm

615

Exhaust temp. at muffler outlet

�F

925

ENGINE PARAMETERS

Rated synchronous RPM

60 Hz

1800

HP at rated KW

60 Hz

109

POWER ADJUSTMENT FOR AMBIENT CONDITIONS

Temperature Deration

3% for every 10 �C above - �C

25

1.65% for every 10 �F above - �F

77

Altitude Deration

1% for every 100 m above - m

182

3% for every 1000 ft. above - ft.

600

RATING: All three phases units are rated at 0.8 power factor. All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply

to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload

capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. kW rating is based on

LPG fuel and may derate with natural gas.


GENERATOR FEATURES

ˆRevolving field heavy duty generator ˆDirectly connected to the engine ˆOperating temperature rise 120 ˚C above a 40 ˚C ambient ˆInsulation is Class H rated at 150 ˚C rise ˆAll prototype models have passed three phase short circuit testing

CONTROL PANEL FEATURES

ˆTWO FOUR LINE LCD DISPLAYS READ: Voltage (all phases) Current (all phases) Power factor kW kVAR Transfer switch status Engine speed Low fuel pressure Run hours Service reminders Fault history Oil pressure Coolant temperature Time and date Low oil pressure shutdown High coolant temperature shutdown Overvoltage Overspeed Low coolant level Low coolant level Not in auto position (flashing light)

ˆINTERNAL FUNCTIONS: I2T function for alternator protection from line to neutral and line to line short circuits Emergency stop Programmable auto crank function 2 wire start for any transfer switch Communicates with the Generac HTS transfer switch Built-in 7 day exerciser Adjustable engine speed at exerciser RS232 port for GenLink® control RS485 port remote communication Canbus addressable Governor controller and voltage regulator are built into the master control board Temperature range -40 ˚C to 70 ˚C

Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). (All ratings in accordance with BS5514, ISO3046, ISO8528 and DIN6271).

70 kW OPERATING DATA

COMMERCIAL 70 kW
KW RATING 70
ENGINE SIZE 6.8 Liter V-10
GENERATOR OUTPUT VOLTAGE/KW - 60Hz 120/240V, 1-phase, 1.0 pf 120/208V, 3-phase, 3.0 pf 277/480V, 3-phase, 3.0 pf KW 70 70 70 AMP 292 243 105 CB Size 300 250 125
GENERATOR LOCKED ROTOR KVA AVAILABLE @ VOLTAGE DIP OF 35% Single phase or 208 3-phase 480V 3-phase 145 160
ENGINE FUEL CONSUMPTION (Natural Gas) Exercise cycle ft3/hr. 25% of rated load ft3/hr. 50% of rated load ft3/hr. 75% of rated load ft3/hr. 100% of rated load ft3/hr.240 260 500 696 1020
ENGINE COOLING Air flow (inlet air including alternator and combustion air) ft3/min. Coolant capacity US gal. Heat rejection to coolant BTU/hr. Max. operating air temp. on radiator ˚C (˚F) Max. ambient temperature ˚C (˚F)5200 4.5 281,500 60 (150) 50 (140)
COMBUSTION AIR REQUIREMENTS Flow at rated power 60 Hz cfm 205
SOUND EMISSIONS IN DBA Exercising at 7 meters Full load at 7 meters 60 73
EXHAUST Exhaust flow at rated output 60 Hz cfm Exhaust temp. at muffler outlet ˚F 615 925
ENGINE PARAMETERS Rated synchronous RPM 60 Hz HP at rated KW 60 Hz 1800 109
POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration 3% for every 10 ˚C above - ˚C 1.65% for every 10 ˚F above - ˚F Altitude Deration 1% for every 100 m above - m 3% for every 1000 ft. above - ft. 25 77 182 600

RATING: All three phases units are rated at 0.8 power factor. All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. kW rating is based on LPG fuel and may derate with natural gas.

 

INTERCONNECTIONS and Installation Layout 70 kWInterconnections for 70 kW Generac Guardian and Installation Layout diagram

NON-TERMINATED

INSTALLATION LAYOUT

UNIT WEIGHT 2185 LBS.

Home Standby GeneratorsHome

Save $$

Portable Generators | Standby Generators |  Air Compressors | UPS Uninterruptible Power Sources  |  Automotive Parts

Sitemap  |  Website Design by Search Engine First Place