Guardian  |  Guardian  Elite  |  QuietSource  |  Commercial  |  Specs  |  Transfer Switches   |  Pricing  |  Email | Home

Diesel Generator Soundproof Quiet Generators Home Standby Emergency Backup Power Generators Diesel Generator Soundproof Quiet Generators Home Standby Emergency Backup Power Generators Backup Generators by Generac Guardian       Commercial Generators    Home Standby Generators by Briggs & StrattonTrailerized Generators


 

KOHLER 30 / 27 kW Liquid-Cooled Standby Generator 30RESAL KOHLER 30 / 27 kW Liquid-Cooled Standby Generator 30RESAL
Generac Guardian Series QT03016 30,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant) Generac Guardian Series QT03016 30,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant)
Buy new: $8,927.00
Usually ships in 24 hours
Generac QT03016ANSX 30,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant) Generac QT03016ANSX 30,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant)
Buy new: $8,927.00
Usually ships in 1 to 2 days
Generac QuietSource Series QT02516 25,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant) Generac QuietSource Series QT02516 25,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant)
Buy new: $7,919.00
Usually ships in 1 to 2 days
Briggs & Stratton 40248 7000-Watt PowerNow Dual Mode Air Cooled Home Standby Generator Briggs & Stratton 40248 7000-Watt PowerNow Dual Mode Air Cooled Home Standby Generator
Buy new: $1,799.99
Usually ships in 1-3 weeks
Generac QT04524ANSC 45,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant) Generac QT04524ANSC 45,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant)
Buy new: $11,673.00
Usually ships in 1 to 2 days

Home  |  email  |   Buy Commercial Generators Online

 

Continuous Standby Power Rating Model #04917 30kW 60 Hz LPV / 27kW 60 Hz NG UL 2200 Listed Power Matched

 

FEATURES

ˆ INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of GENERAC’S success in “IMPROVING POWER BY DESIGN.” But it doesn’t stop there. Total commitment to component testing, reliability testing, environmental testing, destruction and life testing, plus testing to applicable CSA, NEMA, EGSA, and other standards, allows you to choose GENERAC POWER SYSTEMS with the confidence that these ˆ SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION. This state-of-the-art power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque-matching the surge loads to the engine.
ˆ systems will provide superior performance. TEST CRITERIA: >PROTOTYPE TESTED ˆ SINGLE SOURCE SERVICE RESPONSE from Generac’s dealer network provides parts and service know-how for the entire unit, from the engine to the smallest electronic component. You are never on your own when you own a GENERAC POWER SYSTEM.
>SYSTEM TORSIONAL TESTED >ELECTRO-MAGNETIC INTERFERENCE >NEMA MG1-22 EVALUATION ˆ GENERAC TRANSFER SWITCHES. Long life and reliability are synonymous with GENERAC POWER SYSTEMS. One reason for this confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility.
> MOTOR STARTING ABILITY

 

APPLICATION & ENGINEERING DATA Home Standby - 30 kW GENERATOR SPECIFICATIONS

GENERATOR FEATURES

  • Four pole, revolving field generator, directly connected to the engine shaft through a heavy-duty, flexible disc for permanent alignment. 

  • Generator meets temperature rise standards for class “F” insulation as defined by NEMA MG1-22.4 and NEMA MG 1-1.65, while the insulation system meets the requirements for the higher class “H” rating.
  • Unit tested for motor starting ability by measuring instantaneous voltage dip with a wave form data acquisition system.

  • All models utilize an advanced wire harness design for reliable interconnection within the circuitry.

  • Magnetic circuit, including amortisseur windings, tooth and skewed stator design, provides a minimal level of waveform distortion and an electromagnetic interference level which meets accepted requirements for standard AM radio, TV, and marine radio telephone applications.

  • Voltage waveform deviation, total harmonic content of the AC waveform, and balanced T.I.F. (Telephone Influence Factor) have been evaluated to acceptable standards in accordance with NEMA MG1-22. 

  • Alternator is self-ventiliated and of drip-proof guarded construction.

  • Fully life-tested protective systems, including “field circuit and thermal overload protection” and standard main line circuit breakers capable of handling full output capacity.

  • System torsional acceptability confirmed during prototype testing.

GENERATOR SPECIFICATIONS

TYPE ...................................................................... Four-pole, revolving field

ROTOR INSULATION ....................................................................... Class F

STATOR INSULATION ...................................................................... Class H

TOTAL HARMONIC DISTORTION (line to line) ................................. <3.5%

TELEPHONE INTERFERENCE FACTOR (TIF) ..................................... <50

ALTERNATOR ................................................. Self-ventilated and drip-proof

BEARINGS (PRE-LUBED & SEALED) ....................................................... 1

COUPLING .................................................................... Direct, Flexible Disc

LOAD CAPACITY (STANDBY) ............................................................. 100%

LOAD CAPACITY (PRIME) .................................................................. 110%

NOTE: Emergency loading in compliance with NFPA 99, NFPA 110,

paragraph 5-13.2.6. Generator rating and performance in accordance

with ISO8528-5, BS5514, SAE J1349, ISO3046, and DIN6271 standards.

EXCITATION SYSTEM

DIRECT .................................................................. DC excitation system ?

Low-velocity brushes and slip rings ?

VOLTAGE REGULATION ......................................................... Solid-state ?

±1% regulation ?

ENGINE SPECIFICATIONS

MAKE .......................................................................................... GENERAC

MODEL ............................................................................................... 3.0GN

CYLINDERS ...................................................................................... V-6 60°

DISPLACEMENT ........................................................ 3.0 Liter (182 cu. in.)

BORE ............................................................................... 88.9 mm (3.50 in.)

STROKE .......................................................................... 78.7 mm (3.10 in.)

COMPRESSION RATIO ........................................................................ 9.3:1

INTAKE AIR ................................................................... Naturally Aspirated

NUMBER OF MAIN BEARINGS ................................................................ 4

CONNECTING RODS .................................................... 6-Drop forged steel

CYLINDER HEAD .......................................................................... Cast Iron

PISTONS ................................................. 6-Notched Head, Aluminum Alloy

CRANKSHAFT ............................................................................... Cast Iron

VALVE TRAIN

LIFTER TYPE ...................................................................... Hydraulic Roller

INTAKE VALVE MATERIAL ..................................... Aluminized Steel Faced

EXHAUST VALVE MATERIAL .................................................... Steel Faced

HARDENED VALVE SEATS ..................................................................... No

ENGINE GOVERNOR

? ELECTRONIC.............................................................................. Standard

FREQUENCY REGULATION, NO-LOAD TO FULL LOAD ............ 0.5%

STEADY STATE REGULATION .................................................. ±0.25%

LUBRICATION SYSTEM

TYPE OF OIL PUMP ............................................................................ Gear

OIL FILTER ...................................................................... Full flow, cartridge

CRANKCASE CAPACITY ............................................. 4.73 Liters (5.0 qts.)

COOLING SYSTEM

TYPE OF SYSTEM ........................................ Pressurized, closed recovery

WATER PUMP .......................................................... Pre-lubed, self-sealing

TYPE OF FAN ............................................................ Variable speed clutch

NUMBER OF FAN BLADES ....................................................................... 7

DIAMETER OF FAN ............................................................ 432 mm (18 in.)

FUEL SYSTEM

FUEL

? Natural Gas or L.P. Vapor .......................................................... Standard

CARBURETOR ............................................................................ Side draft

SECONDARY FUEL REGULATOR ............ Nat. Gas or L.P. Vapor Systems

AUTOMATIC FUEL LOCKOFF SOLENOID ................................... Standard

OPERATING FUEL PRESSURE VAPOR SYSTEMS ..Nat. Gas 5 to 14” H2O

LP Vapor.....11” to 14” H2O

ELECTRICAL SYSTEM

BATTERY CHARGE ALTERNATOR ................................... 15 Amps at 12 V

STARTER MOTOR .................................................................................. 12 V

RECOMMENDED BATTERY ................................... (1) - 12 V, 90 A.H., 27F

GROUND POLARITY ..................................................................... Negative

Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). Maximum wattage and current are subject to and limited by such factors as fuel Btu content, ambient temperature, altitude, engine power and condition, etc.

Home Standby Generator 30 kW Operating Data

STANDBY
GENERATOR OUTPUT VOLTAGE/KW - 60HzHome Standby - 30
LPNG Amps LP Amps NG
120/240V, 1-phase, 1.0 pf 30 27 250/125 225/112.5
MOTOR STARTING KVA Maximum at 35% instantaneous voltage dip45 40
Main Line Circuit Breaker 150 Amp
FUEL Fuel consumption - 60 Hz--100% Load ft.3 /hr.(gal./hr) m3 /hr.LPNG
160 (4.4) 4.5387 10.96
COOLINGLP NG
Coolant capacity System lit.(US gal.) Coolant flow/min. 60 Hz lit.(US gal.) Heat rejection to coolant BTU/hr. Radiator air flow 60 Hz m3/min. (cfm) Max. operating air temperature onto radiator °F Max. operating ambient temperature °F122,000 11.36 (3.0) 67.76 (17.9) 107,500 119 (4200) 140 120
COMBUSTION AIR REQUIREMENTSLP NG
Flow at rated power 60 Hz m3/min. (cfm)2.55 (90)
EXHAUSTLP NG
Exhaust flow at rated output 60 Hz m3/min. (cfm) Max. recommended back pressure Kpa (Hg) Exhaust temp. at rated output °C (°F)7.4 (262) 5.0 (1.5”) 593 (1100) 6.8 (240) 5.0 (1.5”) 566 (1050)
ENGINELP NG
Rated at RPM 60 Hz HP at rated KW 60 Hz Piston speed 60 Hz m/sec. (ft./min.) BMEP 60 Hz49.7 4.7 (930) 119 1800 45 4.7 (930) 108
POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature -1.65% for every 10°F above - °F Altitude -3.0% for every 1000 ft. above - ft.77 600
SOUND OUTPUT In dB(A) at 23 feet with generator operating at full load71.8
TRANSFER SWITCH SPECIFICATIONS (Transfer switch is not included with this model)

STANDARD ENGINE & SAFETY FEATURES Home Standby -30

ˆHigh Coolant Temperature Automatic Shutdown ˆBattery Charge Alternator ˆLow Coolant Level Automatic Shutdown ˆBattery Cables ˆLow Oil Pressure Automatic Shutdown ˆBattery Tray ˆOverspeed Automatic Shutdown (Solid-state) ˆVibration Isolation of Unit to Mounting Base ˆCrank Limiter (Solid-state) ˆ12 Volt, Solenoid-Activated Starter Motor ˆOil Drain Extension ˆAir Cleaner ˆRadiator Drain Extension ˆFan Guard ˆFactory-Installed Cool Flow Radiator ˆControl Console ˆClosed Coolant Recovery System ˆStainless Steel Flexible Exhaust Connection ˆUV/ Ozone Resistant Hoses ˆMain Line Circuit Breaker ˆRubber-Booted Engine Electrical Connections ˆCritical Exhaust Silencer ˆFuel Lockoff Solenoid ˆBattery Trickle Charger ˆIsochronous Governor ˆAll Aluminum Weather Protective Enclosure ˆSecondary Fuel Regulator (N.G. and L.P.G.) (Locking Type)

Home Standby Control Features:

Home Standby ControlHome Standby Microprocessor
Console Controls
Manual/Auto/Off switch Automatic voltage regulation
Six light LED indicator for Utility voltage sensing
generator status and Utility interrupt delay
fault status (10-second setpoint)
Fuses (panel overload) Engine warm-up
Set exercise time switch (10-second setpoint)
Engine cool-down
(1-minute setpoint)
Seven-day exerciser

 

Design and specifications subject to change without notice. Dimensions shown are approximate. Contact your Guardian dealer for certified drawings. DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES.

UNIT WEIGHT: 1250 lbs.

GENERAC POWERSYSTEMS - All specifications subject to change without notice.

 

Sitemap  |  Website Design by Search Engine First Place