150 kW Tractor-Driven PTO Generator (Single Phase)
|
|||
Taylor Mobile Generator Set - 150 kW, Model# NT150
Buy new: $34,499.99 Usually ships in 6-10 business days |
|||
Taylor Mobile Diesel Generator - 80 kW, 3 Phase, 230 Volts, Model# TM80 3/230
Buy new: $32,999.99 Usually ships in 6-10 business days |
• | All input connections in one single area | • | Watertight state of the art electrical connectors |
• | High coolant temperature shutdown | • | Mainline circuit breaker |
• | Low oil pressure shutdown | • | Oil drain extension to frame rail |
• | Low coolant level automatic shutdown | • | Radiator drain extension |
• | Overspeed automatic shutdown | • | Battery charge alternator |
• | Adjustable cranking timer | • | 2 Amp static battery charger |
• | Adjustable exercise timer | • | Battery and battery cables |
• | Oil drain extension | • | Battery rack |
• | Cool flow radiator | • | Fan and belt guards |
• | Closed coolant recovery system | • | Isochronous governor |
• | UV/Ozone resistant hoses | ||
FEATURES |
• | Innovative design and fully prototype tested | • | Built-in kW, kVAR and power factor meters |
• | UL2200 Listed | • | Watertight electrical connectors |
• | Solid state frequency compensated digital | • | Rodent proof construction |
voltage regulator | • | High efficiency, low distortion Generac designed alternator | |
• | Dynamic and static battery charger | • | Vibration isolated from mounting base |
• | Sound attenuated acoustically designed enclosure | • | Matching Generac transfer switches engineered and |
• | Quiet test for low noise level exercise | tested to work as a system | |
• | Acoustically designed engine cooling system | • | All components easily accessible for maintenance |
• | High flow low noise factory engineered exhaust system | • | Electrostatically applied powder paint |
• | State of the art digital control system | • | H-100 microprocessor control panel |
GENERATOR SPECIFICATIONS
TYPE ..........................................................................................................Synchronous
ROTOR INSULATION ..........................................................................................Class H
STATOR INSULATION ........................................................................................Class H
TOTAL HARMONIC DISTORTION ........................................................................<3.5%
TELEPHONE INTERFERENCE FACTOR (TIF) ........................................................<50
ALTERNATOR OUTPUT LEADS 3 PHASE............................................................4 wire
BEARINGS ....................................................................................................Sealed Ball
COUPLING ..................................................................................................Flexible Disc
LOAD CAPACITY (STANDBY RATING) ..............................................................150 kW
EXCITATION SYSTEM ....................................................................................Brushless
NOTE: Emergency loading in compliance with NFPA 99, NFPA 110,
paragraph 5-13.2.6. Generator rating and performance in accordance
with ISO8528-5, BS5514, SAE J1349, ISO3046, and DIN6271 standards.
GENERATOR FEATURES
Revolving field heavy duty generator
Quiet drive coupling
Operating temperature rise 120 �C above a 40 �C ambient
Insulation is Class H rated at 150 �C rise
All prototype models have passed three phase short circuit testing
VOLTAGE REGULATOR
TYPE ..............................................................................................................Full Digital
SENSING ............................................................................................................3 Phase
REGULATION ......................................................................................................� 1/4%
FEATURES ......................................................................Built into H-100 Control Panel
V/F Adjustable
Adjustable Voltage and Gain
CONTROL PANEL FEATURES
TWO FOUR LINE LCD DISPLAYS READ:
Voltage (all phases) Current (all phases)
Power factor kW
kVAR Transfer switch status
Engine speed Low fuel pressure
Run hours Service reminders
Fault history Oil pressure
Coolant temperature Time and date
Low oil pressure shutdown High coolant temperature shutdown
Overvoltage Overspeed
Low coolant level Low coolant level
Not in auto position (flashing light)
INTERNAL FUNCTIONS:
I2T function for alternator protection from line to neutral and line to line short circuits
Emergency stop
Programmable auto crank function
2 wire start for any transfer switch
Communicates with the Generac HTS transfer switch
Built-in 7 day exerciser
Adjustable engine speed at exerciser
RS232 port for GenLink� control
RS485 port remote communication
Canbus addressable
Governor controller and voltage regulator are built into the master control board
Temperature range -40 �C to 70 �C
ENGINE SPECIFICATIONS
MAKE ................................................................................................................ Generac
MODEL..................................................................................................................V Type
CYLINDERS ................................................................................................................10
DISPLACEMENT ................................................................................................6.8 Liter
BORE ........................................................................................................................3.55
STROKE....................................................................................................................4.17
COMPRESSION RATIO ..............................................................................................9:1
INTAKE AIR SYSTEM........................................................................Naturally Aspirated
VALVE SEATS ..................................................................................................Hardened
LIFTER TYPE ....................................................................................................Hydraulic
GOVERNOR SPECIFICATIONS
TYPE ................................................................................................................Electronic
FREQUENCY REGULATION ..................................................................................� 1%
STEADY STATE REGULATION ............................................................................� 1/2%
ADJUSTMENTS
Speed......................................................................................................Yes
Droop ......................................................................................................Yes
ENGINE LUBRICATION SYSTEM
OIL PUMP ................................................................................................................Gear
OIL FILTER ..........................................................................................Full flow cartridge
CRANKCASE CAPACITY ..................................................................................5 Quarts
ENGINE COOLING SYSTEM
TYPE ....................................................................................................................Closed
WATER PUMP ................................................................................................Belt driven
FAN SPEED..............................................................................................................2000
FAN DIAMETER................................................................................................26 inches
FAN MODE..............................................................................................................Puller
FUEL SYSTEM
FUEL TYPE....................................................................................................Natural gas
CARBURETOR ..............................................................................................Down Draft
SECONDARY FUEL REGULATOR ..................................................................Standard
FUEL SHUT OFF SOLENOID ..........................................................................Standard
OPERATING FUEL PRESSURE..................................................................5� - 14� H2O
ELECTRICAL SYSTEM
BATTERY CHARGE ALTERNATOR ............................................................12V 30 Amp
STATIC BATTERY CHARGER........................................................................12V 2 Amp
RECOMMENDED BATTERY ......................................................................24F 625CCA
SYSTEM VOLTAGE ............................................................................................12 Volts
TWO FOUR LINE LCD DISPLAYS READ: Voltage (all phases) Current (all phases) Power factor kW kVAR Transfer switch status Engine speed Low fuel pressure Run hours Service reminders Fault history Oil pressure Coolant temperature Time and date Low oil pressure shutdown High coolant temperature shutdown Overvoltage Overspeed Low coolant level Low coolant level Not in auto position (flashing light)
INTERNAL FUNCTIONS: I2T function for alternator protection from line to neutral and line to line short circuits Emergency stop Programmable auto crank function 2 wire start for any transfer switch Communicates with the Generac HTS transfer switch Built-in 7 day exerciser Adjustable engine speed at exerciser RS232 port for GenLink® control RS485 port remote communication Canbus addressable Governor controller and voltage regulator are built into the master control board Temperature range -40 ˚C to 70 ˚C
Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). (All ratings in accordance with BS5514, ISO3046, ISO8528 and DIN6271).
COMMERCIAL 150 kW | |||
KW RATING | 150 | ||
ENGINE SIZE | 6.8 Liter V-10 | ||
GENERATOR OUTPUT VOLTAGE/KW - 60Hz 120/240V, 1-phase, 1.0 pf 120/208V, 3-phase, 3.0 pf 277/480V, 3-phase, 3.0 pf | KW 150 150 150 | AMP 625 520 226 | CB Size 700 600 250 |
GENERATOR LOCKED ROTOR KVA AVAILABLE @ VOLTAGE DIP OF 35% Single phase or 208 3-phase 480V 3-phase | 345 390 | ||
ENGINE FUEL CONSUMPTION (Natural Gas) Exercise cycle ft3/hr. 25% of rated load ft3/hr. 50% of rated load ft3/hr. 75% of rated load ft3/hr. 100% of rated load ft3/hr. | 348 556 1070 1491 2061 | ||
ENGINE COOLING Air flow (inlet air including alternator and combustion air) ft3/min. Coolant capacity US gal. Heat rejection to coolant BTU/hr. Max. operating air temp. on radiator ˚C (˚F) Max. ambient temperature ˚C (˚F) | 9750 4.5 568,800 60 (150) 50 (140) | ||
COMBUSTION AIR REQUIREMENTS Flow at rated power 60 Hz cfm | 410 | ||
SOUND EMISSIONS IN DBA Exercising at 7 meters Full load at 7 meters | 62 76 | ||
EXHAUST Exhaust flow at rated output 60 Hz cfm Exhaust temp. at muffler outlet ˚F | 1200 925 | ||
ENGINE PARAMETERS Rated synchronous RPM 60 Hz HP at rated KW 60 Hz | 3600 232 | ||
POWER ADJUSTMENT FOR AMBIENT CONDITIONS Temperature Deration 3% for every 10 ˚C above - ˚C 1.65% for every 10 ˚F above - ˚F Altitude Deration 1% for every 100 m above - m 3% for every 1000 ft. above - ft. | 25 77 182 600 |
RATING: All three phases units are rated at 0.8 power factor. All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. kW rating is based on LPG fuel and may derate with natural gas.
NON-TERMINATED UNIT WEIGHT 2666 LBS.