40 kW 40,000 Watt Single Phase Generators - Click here for the

Diesel Generator Soundproof Quiet Generators Home Standby Emergency Backup Power Generators  Backup Generators by Generac Guardian       Commercial Generators    Home Standby Generators by Briggs & StrattonTrailerized Generators

 

Commercial 3 Phase Generators

Search Results
Showing 1 - 10 of 11 results for "generac commercial" in Power Generators.
Generac 5870 8,000 Watt Air-Cooled Propane/Natural Gas Powered Home Automatic Standby Generator With Transfer Switch (CARB Compliant)Generac 5870 8,000 Watt Air-Cooled Propane/Natural Gas Powered Home Automatic Standby Generator With Transfer Switch (CARB Compliant)
Buy new: $2,159.00
Usually ships in 24 hours
Guardian QuietSource Liquid-Cooled Light Commercial 18,000 Watt Stand By Generator With Gray Aluminum Enclosure 5399Guardian QuietSource Liquid-Cooled Light Commercial 18,000 Watt Stand By Generator With Gray Aluminum Enclosure 5399
Buy new: $6,971.35
Usually ships in 24 hours
Generac QT04842ANAX 48,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby GeneratorGenerac QT04842ANAX 48,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator
Buy new: $13,871.00
Usually ships in 1 to 2 days
Generac Commercial Series Liquid-Cooled Standby Generator 60 kW, 277/480 Volts, LP, Model# QT06030KVSNGenerac Commercial Series Liquid-Cooled Standby Generator 60 kW, 277/480 Volts, LP, Model# QT06030KVSN
Buy new: $14,799.99
Usually ships in 3-5 weeks
Generac Guardian Series QT03016 30,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant)Generac Guardian Series QT03016 30,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant)
Buy new: $8,927.00
Usually ships in 24 hours
Generac QT04524Y 45,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant)Generac QT04524Y 45,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant)
Buy new: $12,681.23
Usually ships in 24 hours
Generac 4582-2 Ultra Source 15,000 Watt Portable Generator (CARB Compliant)Generac 4582-2 Ultra Source 15,000 Watt Portable Generator (CARB Compliant)
Buy used from: $4,500.00
Generac QT03016ANSX 30,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant)Generac QT03016ANSX 30,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant)
Buy new: $8,927.00
Usually ships in 1 to 2 days
Generac QuietSource Series QT02516 25,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant)Generac QuietSource Series QT02516 25,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant)
Buy new: $7,919.00
Usually ships in 1 to 2 days
Generac QT02516ANSX 25,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant)Generac QT02516ANSX 25,000 Watt Liquid Cooled Propane/Natural Gas Powered Home Automatic Standby Generator (CARB Compliant)
Buy new: $7,919.00
Usually ships in 1 to 2 days
1   2   Next > >

 

Guardian  |  Guardian  Elite  |  QuietSource  |  Commercial  |  Specs  |  Transfer Switches   |  Pricing  |  Email

FAQ's

  • The generator that I've chosen has a 100-amp automatic transfer switch. What if I have 200-amp service in my home?
    It is always recommended that emergency circuits be isolated by the emergency load center. An isolated sub-panel will prevent the possibility of the generator becoming overloaded. Thus, the system will respond automatically.
  • Will 200-amp automatic transfer switches be available for the air-cooled models, and the 15 kW and 20 kW liquid-cooled Residential Emergency Home Standby generators?
    No. It is not electrically necessary. The outputs of these generators are safely carried with the 100-amp automatic transfer switch.

(Pricing below may not include shipping for all states - call ahead for shipping rates) 

Liquid Cooled Gas Engine Generator Sets Naturally Aspirated Gaseous Fueled UL 2200 Listed Quiet-Test ModeQuiet-Test Mode For Low Noise Exercise


For Low Noise Exercise - 60 dB(A) at 23 feet-60 dB(A) at 23 feet

STANDARD EQUIPMENT

Liquid Cooled Gas Engine Generator Sets

• All input connections in one single area

• High coolant temperature shutdown

• Low oil pressure shutdown

• Low coolant level automatic shutdown

• Overspeed automatic shutdown

• Crank timer

• Exercise timer

• Oil drain extension

• Cool flow radiator

• Closed coolant recovery system

• UV/Ozone resistant hoses

• Watertight state of the art electrical connectors

• Mainline circuit breaker

• Radiator drain extension

• Battery charge alternator

• 2 Amp static battery charger

• Battery and battery cables

• Battery rack

• Fan and belt guards

• Isochronous governor

Naturally Aspirated Gaseous Fueled

• Innovative design and fully prototype tested

• UL2200 Listed

• Solid state frequency compensated digital

voltage regulator

• Dynamic and static battery charger

• Sound attenuated acoustically designed enclosure

• Quiet test for low noise level exercise

• Acoustically designed engine cooling system

• High flow low noise factory engineered exhaust system

R100 digital control panel

• State of the art digital control system

• Watertight electrical connectors

• Rodent proof construction

• High efficiency, low distortion Generac designed alternator

• Vibration isolated from mounting base

• Matching Generac transfer switches engineered and

tested to work as a system

• All components easily accessible for maintenance

• Electrostatically applied powder paint

APPLICATION & ENGINEERING DATA 40 kW GENERATOR SPECIFICATIONS

TYPE ..........................................................................................................Synchronous

ROTOR INSULATION ..........................................................................................Class H

STATOR INSULATION ........................................................................................Class H

TOTAL HARMONIC DISTORTION ........................................................................<3.5%

TELEPHONE INTERFERENCE FACTOR (TIF) ........................................................<50

ALTERNATOR OUTPUT LEADS 3 PHASE............................................................4 wire

BEARINGS ....................................................................................................Sealed Ball

COUPLING ..................................................................................................Flexible Disc

LOAD CAPACITY (STANDBY RATING) ................................................................40 kW

EXCITATION SYSTEM............................................................................................Direct

NOTE: Generator rating and performance in accordance with ISO8528-5,

BS5514, SAE J1349, ISO3046, and DIN6271 standards.

GENERATOR FEATURES

Revolving field heavy duty generator

Directly connected to the engine

Operating temperature rise 120 °C above a 40 °C ambient

Insulation is Class H rated at 150 °C rise

All models are fully prototyped tested

VOLTAGE REGULATOR

TYPE ................................................................................................................Electronic

SENSING ....................................................................................................Single Phase

REGULATION ..........................................................................................................± 1%

FEATURES................................................................................................V/F Adjustable

Adjustable Voltage and Gain

LED Indicators

CONTROL PANEL FEATURES

SIX LED INDICATOR LIGHTS:

Overcrank shutdown Overspeed shutdown

Low coolant level shutdown High coolant temperature shutdown

Low oil pressure shutdown Low battery voltage

System ready for operation No utility sensing

Exerciser not set (in auto mode only) Low fuel pressure

Delay on utility failure for engine start Engine warmup before transfer

Delay to retransfer to utility Delay to retransfer to utility

Engine cooldown timer

INTERNAL FUNCTIONS:

3 position switch (auto, off and manual)

2 wire start for any transfer switch

Communicates with the Generac RTS transfer switch

Built-in 7 day exerciser

Selectable engine speed at exercise

Governor controller is built into the master control board

Temperature range -40 °C to 70 °C

ENGINE SPECIFICATIONS

MAKE ................................................................................................................ Generac

MODEL..................................................................................................................V Type

CYLINDERS ..................................................................................................................6

DISPLACEMENT ................................................................................................3.9 Liter

BORE ........................................................................................................................3.91

STROKE....................................................................................................................3.31

COMPRESSION RATIO ..........................................................................................9.1:1

INTAKE AIR SYSTEM........................................................................Naturally Aspirated

VALVE SEATS ......................................................................................Precision ground

LIFTER TYPE ....................................................................................................Hydraulic

GOVERNOR SPECIFICATIONS

TYPE ................................................................................................................Electronic

FREQUENCY REGULATION ..................................................................................± 1%

STEADY STATE REGULATION ............................................................................± 1/2%

ADJUSTMENTS

Speed......................................................................................................Yes

Droop ......................................................................................................Yes

ENGINE LUBRICATION SYSTEM

OIL PUMP ................................................................................................................Gear

OIL FILTER ..........................................................................................Full flow cartridge

CRANKCASE CAPACITY ..................................................................................4 Quarts

ENGINE COOLING SYSTEM

TYPE ....................................................................................................................Closed

WATER PUMP ................................................................................................Belt driven

FAN SPEED..............................................................................................................2190

FAN DIAMETER................................................................................................22 inches

FAN MODE............................................................................................................Pusher

FUEL SYSTEM

FUEL TYPE ..........................................................................Natural gas, propane vapor

CARBURETOR ..............................................................................................Down Draft

SECONDARY FUEL REGULATOR ..................................................................Standard

FUEL SHUT OFF SOLENOID ..........................................................................Standard

OPERATING FUEL PRESSURE..................................................................5” - 14” H2O

ELECTRICAL SYSTEM

BATTERY CHARGE ALTERNATOR ............................................................12V 30 Amp

STATIC BATTERY CHARGER ..............................................................................2 Amp

RECOMMENDED BATTERY ......................................................................24F 625CCA

SYSTEM VOLTAGE ............................................................................................12 Volts

GENERATOR FEATURES

ˆRevolving field heavy duty generator ˆDirectly connected to the engine ˆOperating temperature rise 120 ˚C above a 40 ˚C ambient ˆInsulation is Class H rated at 150 ˚C rise ˆAll models are fully prototyped tested

CONTROL PANEL FEATURES

ˆSIX LED INDICATOR LIGHTS: Overcrank shutdown Overspeed shutdown Low coolant level shutdown High coolant temperature shutdown Low oil pressure shutdown Low battery voltage System ready for operation No utility sensing Exerciser not set (in auto mode only) Low fuel pressure Delay on utility failure for engine start Engine warmup before transfer Delay to retransfer to utility Delay to retransfer to utility Engine cooldown timer

ˆINTERNAL FUNCTIONS: 3 position switch (auto, off and manual) 2 wire start for any transfer switch Communicates with the Generac RTS transfer switch Built-in 7 day exerciser Selectable engine speed at exercise Governor controller is built into the master control board Temperature range -40 ˚C to 70 ˚C

Rating definitions - Standby: Applicable for supplying emergency power for the duration of the utility power outage. No overload capability is available for this rating. (All ratings in accordance with BS5514, ISO3046 and DIN6271). (All ratings in accordance with BS5514, ISO3046, ISO8528 and DIN6271).

KW RATING 40

ENGINE SIZE 3.9 Liter V-6

GENERATOR OUTPUT VOLTAGE/KW - 60Hz KW AMP CB Size

120/240V, 1-phase, 1.0 pf 40 167 175

120/208V, 3-phase, 3.0 pf 40 139 150

277/480V, 3-phase, 3.0 pf 40 60 70

GENERATOR LOCKED ROTOR KVA

AVAILABLE @ VOLTAGE DIP OF 35%

Single phase or 208 3-phase 80

480V 3-phase 90

ENGINE FUEL CONSUMPTION (Natural Gas)

Exercise cycle ft3/hr. 93

25% of rated load ft3/hr. 148

50% of rated load ft3/hr. 285

75% of rated load ft3/hr. 397

100% of rated load ft3/hr. 555

ENGINE COOLING

Air flow (inlet air including alternator and combustion air) ft3/min. 2725

Coolant capacity US gal. 3.0

Heat rejection to coolant BTU/hr. 153,000

Max. operating air temp. on radiator °C (°F) 60 (150)

Max. ambient temperature °C (°F) 50 (140)

COMBUSTION AIR REQUIREMENTS

Flow at rated power 60 Hz cfm 118

SOUND EMISSIONS IN DBA

Exercising at 7 meters 60

Full load at 7 meters 73

EXHAUST

Exhaust flow at rated output 60 Hz cfm 360

Exhaust temp. at muffler outlet °F 925

ENGINE PARAMETERS

Rated synchronous RPM 60 Hz 1800

HP at rated KW 60 Hz 62

POWER ADJUSTMENT FOR AMBIENT CONDITIONS

Temperature Deration

3% for every 10 °C above - °C 25

1.65% for every 10 °F above - °F 77

Altitude Deration

1% for every 100 m above - m 182

3% for every 1000 ft. above - ft. 600

RATING: All three phases units are rated at 0.8 power factor. All single phase units are rated at 1.0 power factor. STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifications are subject to change without notice. KW rating is based on LPG Fuel and may derate with natural gas.

 

INTERCONNECTIONS 40 kW

INSTALLATION LAYOUT


UNIT WEIGHT 1658 LBS.

40 kW 60 Hz Liquid Cooled Gas Engine Generator Sets Generac Guardian

30kW - 3.0L Liquid Cooled 40kW - 3.9L Liquid Cooled 50kW - 3.0L Liquid Cooled 55kW - 5.4L Liquid Cooled 70kW - 3.9L Liquid Cooled 70kW - 6.8L Liquid Cooled 80kW - 5.4L Liquid Cooled 100kW - 5.4L Liquid Cooled 100kW - 6.8L Liquid Cooled 130kW - 6.8L Liquid Cooled 150kW - 6.8L Liquid Cooled 11 kW 15, 20 & 25 kW 30 kW & 40 kWTransfer Switches  |  Generator Control Panel


Home

Call Toll Free 1-800-931-0552 - Out of Country: 720-322-0500 Engine Classifieds

Sitemap  |  Website Design by Search Engine First Place