GENERATOR Model 04389(7kW)
Model 04456 (12kW) |
Model 04390 (15kW†) |
Rated Maximum Continuous
Power Capacity (LP)................................... 7,000 Watts*
12,000 Watts* |
15,000 Watts* |
Rated Maximum Continuous
Power Capacity (NG)...................................6,000 Watts*
12,000 Watts* |
13,000 Watts* |
Rated
Voltage................................................................................................120/240
120/240 |
120/240 |
Rated Maximum Continuous
Load Current |
|
120 Volts
................................................................................................
50.0 NG/58.3 LP 100.0 NG/100.0 LP |
108.3 NG/125.0 LP |
240 Volts
................................................................................................
25.0 NG/29.2 LP 50.0 NG/ 50.0 LP |
54.2 NG/62.5 LP |
Main Line Circuit Breaker
.............................................................................
30 Amp 50 Amp |
60 Amp/70 Amp† |
Phase
.................................................................................................................
1 1 |
1 |
Number of Rotor Poles
.......................................................................................2
2 |
2 |
Rated AC Frequency
........................................................................................60Hz
60Hz |
60Hz |
Power Factor
.......................................................................................................1
1 |
1 |
Battery Requirement (not
included)
..........................................................Group 26/26R
Group 26/26R |
Group 26/26R |
12 Volts and 12 Volts and |
12 Volts and |
350 Cold-cranking 525
Cold-cranking |
525 Cold-cranking |
Amperes Minimum Amperes
Minimum |
Amperes Minimum |
Shipping Weight (Includes
Transfer Switch) ..............................................
375Pounds 470 Pounds |
487 Pounds |
Dimensions (L" x
W" x
H").......................................................................
48 x 24 x 28-1/4 48 x 24 x 28-1/4 |
48 x 24 x 28-1/4 |
Sound output in dB(A) at 23
ft. with generator operating at full load................ 68 70.5 |
71.5 |
†15kW on LP fuel requires
electrical upgrade kit 04578. Kit includes power harnesses and 70 amp
2-pole circuit breaker. |
|
ENGINE Model 04389 (7kW)
Model 04456 (12kW) |
Model 04390 (15kW) |
Type of
Engine........................................................................................GENERAC
OHVI GENERAC OHVI V-TWIN |
GENERAC OHVI V-TWIN |
Number of
Cylinders...........................................................................................
1 2 |
2 |
Rated
Horsepower.................................................................................
14.5 @ 3,600 rpm 26 @ 3,600 rpm |
30 @ 3,600 rpm |
Displacement...................................................................................................410cc
763cc |
992cc |
Cylinder
Block........................................................................................
Aluminum w/Cast Aluminum w/Cast |
Aluminum w/Cast |
Iron Sleeve Iron Sleeve |
Iron Sleeve |
Valve
Arrangement..................................................................................
Overhead Valve Overhead Valve |
Overhead Valve |
Ignition
System..................................................................................
Solid-state w/Magneto Solid-state w/Magneto |
Solid-state w/Magneto |
Compression
Ratio..........................................................................................
8.6:1 9.5:1 |
9.5:1 |
Starter............................................................................................................
12 Vdc 12 Vdc |
12Vdc |
Oil Capacity Including
Filter.....................................................................
Approx. 1.7 Qts Approx. 1.7 Qts. |
Approx. 1.7 Qts. |
Operating
RPM...............................................................................................
3,600 3,600 |
3,600 |
Fuel Consumption |
|
Natural Gas
.................... cu.ft./hr. |
|
........................................
1/2 Load 66 152 |
156 |
........................................
Full Load 119 215 |
220 |
Liquid
Propane.................ft3/hr(gal/hr) |
|
.........................................1/2
Load 30(0.82) 56(1.53) |
58(1.58) |
.........................................Full
Load 54(1.47) 76(2.08) |
88(2.40) |
Required fuel pressure to
generator fuel inlet at all load ranges - 5 to 7 inches of water column
for natural gas, 11 to 14 inches of water col |
umn for LP gas |
CONTROLS |
|
Mode Switch |
|
-Auto
..............................................................................................................................................
Automatic Start on Utility |
|
failure/7 day exerciser |
|
-Off
...........................................................................................................................................
Stops unit. Power is removed |
|
Control and charger still
operate |
|
-Manual/Test (start)
......................................................................................................................Start
with starter control, unit |
|
stays on. If utility fails,
transfer |
|
to load takes place. |
|
Engine Start Sequence Cyclic
cranking: 7 sec. on, 7 rest |
|
(90 sec. maximum duration) |
|
Engine Warm-up
....................................................................................................................................................
10 seconds |
|
Engine Cool-Down
....................................................................................................................................................
1 minute |
|
Starter Lock-out
.......................................................................................................................................
Starter cannot re-engage until |
|
5 sec. after engine has
stopped. |
|
2.5 Amp Timed Trickle
Battery Charger
..................................................................................................................
Standard |
|
Automatic Voltage Regulator
w/Overvoltage Protection
............................................................................................
Standard |
|
Automatic Low Oil Pressure
Shutdown
.....................................................................................................................
Standard |
|
Overspeed Shutdown
...........................................................................................................................................
Standard, 72Hz |
|
High Temperature Shutdown
....................................................................................................................................
Standard |
|
Overcrank Protection
................................................................................................................................................
Standard |
|
Safety Fuse
..............................................................................................................................................................
Standard |
|
Rating definitions -
Standby: Applicable for supplying emergency power for the duration of
the utility power outage. No overload capability is available for this
rating. (All ratings in accordance with |
BS5514, ISO3046 and
DIN6271). * Maximum wattage and current are subject to and limited by
such factors as fuel Btu content, ambient temperature, altitude, engine
power and condition, etc. Maximum |
power decreases about 3.5
percent for each 1,000 feet above sea level; and also will decrease
about 1 percent for each 12° C (10° F) above 15.5° C (60°F).
Home Standby - 7kW - 12kW -
15kW
TRANSFER SWITCH &
EMERGENCY LOAD CENTER Model
04389 (7kW) Model 04456 (12kW) Model 04390 (15kW)
No. of Poles
...........................................................................
2 ........................................... 2
........................................... 2
Current Rating (amps)
.......................................................... 100
..........................................100
......................................... 100
Voltage Rating (VAC)
........................................................... 250
......................................... 250
......................................... 250
Utility Voltage Monitor
(fixed)
-Pick-up
................................................. 70%
....................................... 70%
........................................ 70%
-Dropout
................................................ 60%
........................................ 60%
........................................ 60%
Return to Utility
....................................... approx. 13 sec.
....................... approx. 13 sec. ....................... approx.
13 sec.
Exerciser weekly for 12
minutes ...................................... Standard
................................ Standard
................................. Standard
UL Listed
..........................................................................
Standard ................................ Standard
................................. Standard
Dimensions (H” x W” x D”)
........................................... 26.5 x 12.5 x 7
...................... 26.5 x 12.5 x 7 ....................... 26.5 x
12.5 x 7
Total of Pre-wired Circuits
...................................................... 8
........................................... 10
........................................... 12
No. 15A 120V
..................................................... 5
........................................... 3
............................................. 5
No. 20A 120V
..................................................... 1
........................................... 3
............................................. 3
No. 15A 240V
..................................................... -
........................................... -
............................................ -
No. 20A 240V
..................................................... -
........................................... 1
............................................ 1
No. 30A 240V
..................................................... 1
........................................... 1
........................................... 1
Circuit Breaker Protected
Available RMS Symmetrical
Fault Current @ 250 Volts
........................................ 10,000
.................................... 10,000
.................................... 10,000
Transfer Switch Features
• Electrically operated,
mechanically-held contacts for fast, positive connections. •
Rated for all classes of load, 100% equipment rated, both
inductive and resistive. • 2 pole, 250 VAC contactors. •
160 millisecond transfer time. • Dual coil design. •
Main contacts are silver plated or silver alloy to resist welding and