Air Cooled
Home Generators
7, 12, 15 kW (view specs)
ORDER ONLINE NOW!
Yes, you can! (Install it yourself).
Home Standby Units, air cooled, pre-packaged system
includes:
-
Fully pre-wired 30 foot
conduit for hook up to external connect & mount box.
-
The GUARDIAN automatic
transfer switch has the emergency load center built-in. No other
generators manufacturer offers anything like it.
-
Transfer switch with
built-in load center connects to home's main panel with a 2 foot
pre-wired conduit.
-
Connect & mount external
box is outdoor rated and comes pre-wired to generator controls and main
line circuit breaker.
-
1 foot flexible fuel line
for connection from rigid piper to generator fuel inlet.
-
Tough composite mounting pad
eliminates the need to pour concrete. Won't deteriorate over years
of exposure to the elements.
Air Cooled Generators
Click here for
specifications
Please allow a minimum of 14 days for shipment at this time.
|
|
|
|
- Quiet, powerful
Generac OHVI single-cylinder or V-Twin engines
fueled by natural gas or LP gas.
- UL Listed
remote-mounted pre-wired automatic transfer
switch with 8, 10 or 12 circuit emergency load
center for fast and efficient unattended
transfer to generator when utility power fails.
- A standard weather
protective enclosure with sound-absorbing panels
protects generator from harmful weather and also
reduces exterior noise levels. Includes key
locks for security.
- Hinged top and
removable front panel for easy serviceability.
- Built-in charger
maintains battery at optimum performance level.
- Automatic safety
shutdowns protect engine and generator in event
of low oil pressure, high temperature, overspeed
and/or overcrank.
- Automatic
seven-day exerciser runs the system for twelve
minutes weekly to maintain top running
condition.
- Installation
system includes the pre-wired automatic transfer
switch with built-in load center, 30' and 2'
wiring harnesses, pre-wired external connection
box, 1' flexible fuel line,
"Do-It-Yourself" installation guide
and a composite mounting pad.
|
|
|
|
|
|
|
|
|
|
|
Controls |
|
|
Start/Stop
Control |
Cyclic
cranking: 7 seconds on, 7 seconds
rest. 90 seconds overcrank
protection. |
Automatic
Low Oil Shutdown |
Standard |
Overspeed
Shutdown |
Standard,
72 Hz |
Overcrank
Protection |
Standard |
Automatic
Voltage Regulator with Over-Voltage
Protection |
Standard |
Engine
Warmup |
10
seconds |
Engine
Cool-Down |
1
minute |
Safety
Fuse |
Standard |
Starter
Lockout |
Starter
cannot re-engage until 5 seconds
after the engine has stopped |
2
Amp Timed Trickle Battery Charger |
Standard |
Auto
Switch |
Utility
failure/7 day exercise |
Off
Switch |
Stops
unit. Power is removed. Control and
charger still operate |
Manual
/ test |
Start
with starter control, unit stays on.
If utility fails,transfer to load
takes place |
|
|
|
|
|
|
|
|
Transfer
Switch |
|
|
No.
of Poles |
2 |
Current
Rating (amps) |
100 |
Voltage
Rating (VAC) |
250 |
Utility
Voltage Monitor (fixed)
Pick-up
Drop out |
80%
60% |
Return
to Utility |
Approx.
13 seconds |
Exercises
7 minutes weekly |
Standard |
UL
Listed |
Standard |
Dimensions
(H" x W" x D") |
26.5
x 12.5 x 7 |
|
|
|
Go
to 7, 12 & 15 kW specifications PDF |
|
|
|
|
|
|
|
|
Controls |
|
|
Start/Stop
Control |
Cyclic
cranking: 7 seconds on, 7 seconds rest. 90
seconds overcrank protection. |
Automatic
Low Oil Shutdown |
Standard |
Overspeed
Shutdown |
Standard,
70 Hz |
Overcrank
Protection |
Standard |
Automatic
Voltage Regulator with Over-Voltage
Protection |
Standard |
Engine
Warmup |
15
seconds |
Engine
Cool-Down |
1
minute |
Safety
Fuse |
Standard |
|
|
Safety
Fuse |
Standard |
Starter
Lockout |
Starter
cannot re-engage until 5 seconds after
engine has stopped |
2
Amp Timed Trickle Battery Charger |
Standard |
Auto
Switch |
Utility
failure/7 day exercise |
Off
Switch |
Stops
unit. Power is removed. Control and charger
still operate |
Manual
/ Test |
Start
with starter control, unit stays on. If
utility fails, transfer to load takes place |
|
|
|
Go
to 15 & 20 KW specifications PDF |
|
|
|
|
|
|
|
|
Controls |
|
|
Start
/ Stop Control |
Cyclic
cranking: 7 seconds on, 7 seconds rest. 90
seconds overcrank protection. |
Automatic
Low Oil Shutdown |
Standard |
Overspeed
Shutdown |
Standard,
70 Hz |
Overcrank
Protection |
Standard |
Automatic
Voltage Regulator with Over-Voltage
Protection |
Standard |
Engine
Warmup |
15
seconds |
Engine
Cool-Down |
1
minute |
Safety
Fuse |
Standard |
Starter
Lockout |
Starter
cannot re-engage until 5 seconds after
engine has stopped |
2
Amp Timed Trickle Battery Charger |
Standard |
Mode
Switch: Auto Switch |
Utility
failure/7 day exerciser |
Auto
Switch |
Utility
failure/7 day exercise |
Off
Switch |
Stops
unit. Power is removed. Control and charger
still operate |
Manual
/ Test |
Start
with starter control, unit stays on. If
utility fails, transfer to load takes place |
|
|
|
Go
to 25 kW specifications PDF |
|
|
|
|
|
|
|
Controls |
|
|
Start
/ Stop Control |
Cyclic
cranking: 7 seconds on, 7 seconds rest. 90
seconds overcrank protection. |
Automatic
Low Oil Shutdown |
Standard |
Overspeed
Shutdown |
Standard,
70 Hz |
Overcrank
Protection |
Standard |
Automatic
Voltage Regulator with Over-Voltage
Protection |
Standard |
Engine
Warmup |
15
seconds |
Engine
Cool-Down |
1
minute |
Safety
Fuse |
Standard |
Starter
Lockout |
Starter
cannot re-engage until 5 seconds after
engine has stopped |
2
Amp Timed Trickle Battery Charger |
Standard |
Auto
Switch |
Utility
failure/7 day exercise |
Off
Switch |
Stops
unit. Power is removed. Control and charger
still operate |
Manual
/ Test |
Start
with starter control, unit stays on. If
utility fails, transfer to load takes place |
|
|
|
Go
to 45 kW spec PDF |
|
|
|
GUARDIAN
Portable
Generator Model |
12500 |
15000 |
Model
Number |
04451 |
04582 |
Rated
Watts |
12500 |
15000 |
Surge
Watts |
18750 |
22500 |
Voltage
(Vac) |
120/240 |
120/240 |
Output
(A) |
104/52 |
125/62.5 |
Engine
Type |
Generac
V-Twin
OHVI 760cc
27 HP
Electric Start |
Generac
V-Twin
OHVI 992cc
30 HP
Electric Start |
Weight |
417 |
450 |
Dimensions
(H” x W” x L”)
Fully assembled with handle and wheel kit |
38.5
x 30.75 x 48.5 |
38.5
x 30.75 x 48.5 |
Full
Pressure Lubrication |
X |
X |
Single
Point Lifting |
X |
X |
Spin-on
Oil Filter |
X |
X |
Automotive
3-stage Air Filtration |
X |
X |
Automatic
Idle Control |
X |
X |
Lifetime
Carbon Excitation Brushes |
X |
X |
Low
Oil Pressure Shutdown |
X |
X |
Automatic
Voltage Regulation (AVR) |
X |
X |
Solid
State Volt. Regulator |
X |
X |
GFI
Protection |
X |
X |
Anti-Vibration
System |
X |
X |
Circuit
Breakers |
X |
X |
Battery
Charge Cables |
X |
X |
Maintenance
Free Battery |
X |
X |
Full
1-1/4” Tubular Frame |
X |
X |
Pneumatic
Wheel Kit |
X |
X |
Electronic
Governor |
X |
X |
MSRP
(Suggested Price) |
$2,475.00 |
$2,715.00 |
|
|
|
|